NFPA 704 Ratings for 50 Common Chemicals (Printable Chart)

Last Updated: 2026-11-03

Answer Capsule: This NFPA 704 chemical list gives health, flammability and instability ratings and special symbols for 50 common chemicals, from gasoline at 1-3-0 to sulfuric acid at 3-0-2 with W. Ratings marked with an asterisk vary by supplier, so confirm them against the SDS for your exact product. The facility owner assigns the final rating; NFPA 704 provides only the criteria.

Here is a call Print Pro AZ gets every week. A facility manager has a chemical inventory list from the insurance audit, a fire inspection on the calendar, and no idea what numbers go on the diamonds. She has searched for an NFPA 704 chemical list and found six charts that disagree with each other.

They disagree for a reason. NFPA 704 does not publish ratings for chemicals. It publishes criteria, and every supplier applies those criteria to its own product. The result is a chart that is mostly consistent, with a handful of chemicals where you have to check the SDS yourself.

This is that chart. Fifty chemicals grouped the way they show up in real storage rooms, with the rating, the special symbol, the supplier variation where it exists, and the Print Pro AZ part number for the matching sign. Brent Hanke built it from the same data Print Pro AZ uses to work out composite room ratings for customers. The printable version is the free NFPA 704 Diamond Field Guide; use the download form on this page to get it.

How Do You Read This NFPA 704 Chart?

Each row gives a rating in the order health, flammability, instability, written as three numbers like 1-3-0, followed by any special hazard symbol. Blue health is the first number, red flammability the second, yellow instability the third, and the white square symbol comes last.

The numbers run 0 for no hazard to 4 for severe. Health 4 means a very short exposure could cause death or major residual injury. Flammability 4 means a flash point below 73 F with a boiling point below 100 F, or a flammable gas. Instability 4 means the material is readily capable of detonation at normal temperature and pressure.

The full criteria for every level are in the pillar guide to how to read the NFPA 704 diamond.

The "Print Pro AZ part" column is the stock sign that carries that rating. Where it says "blank + kit," the rating is uncommon enough that you build it from a blank diamond and numbers kit. Where it says "custom," Print Pro AZ prints it to order because the rating depends on your concentration.

Why Do Suppliers Disagree on Some NFPA Ratings?

Suppliers disagree because NFPA 704 gives the criteria and leaves the rating to whoever prepares the SDS. Two suppliers of the same solvent can read the same toxicity data and land on health 1 and health 2. Concentration matters too: 3% hydrogen peroxide is 1-0-0, and 30% is 3-0-1 with OX.

**Every chemical marked with an asterisk (*) in the chart below is one where suppliers commonly differ.** For those, the rating shown is the most common one Print Pro AZ sees, not the single correct answer. Pull the SDS for the exact product and concentration you stock. Section 16 often lists the NFPA rating outright; if not, take health from Section 11, flammability from Section 9, instability from Section 10, and special hazards from Sections 5 and 9.

Callout: Never convert a GHS category number into an NFPA number. GHS Category 1 is the most severe and NFPA 1 is the least severe, so a direct copy comes out backwards and puts a 1 on a drum that should carry a 4.

Preview of the NFPA 704 Diamond Field Guide PDF
Free download · 2-page field guide

Print the NFPA 704 Diamond Field Guide

A 2-page field card: how to read every quadrant, the three legal special symbols, sign size by viewing distance, and NFPA 704 ratings for 50 common chemicals with the matching part number. Print it and tape it inside the chemical room door.

The download link appears instantly. No spam, and you can unsubscribe anytime.

NFPA 704 diamond sign printed by Print Pro AZ
NFPA 704 placards · printed in Phoenix

Need placards for a chemical room? Send your inventory, get a quote in one business day.

Attach your chemical inventory or SDS list. Print Pro AZ works out the room rating, prints the NFPA 704 placards on vinyl or aluminum, and ships the same week.

Optional. PDF, Excel, CSV, DWG or images, up to 20 MB. Chemical inventory spreadsheets and SDS binders are perfect.

No commitment. A real person replies within one business day.

NFPA 704 Ratings for 50 Common Chemicals

The chart is grouped by how the chemicals are stored: fuels, solvents, acids, bases, oxidizers and pool chemicals, gases, and everything else. Asterisks mark supplier variation, as explained above.

Fuels and Oils

Chemical Rating (H-F-I) Special Supplier variation Print Pro AZ part
Gasoline 1-3-0 none SS-045
Diesel* 0-2-0 none also 1-2-0 or 2-2-0 SS-001 / SS-009
Kerosene* 0-2-0 none suppliers differ SS-005
Jet A 1-2-0 none SS-001
Propane / LPG* 1-4-0 none some SDS 2-4-0 SS-013 / SS-002
Natural gas 1-4-0 SA on some SS-013
Motor and hydraulic oil 0-1-0 none SS-017
Used oil 1-1-0 none SS-011

Gasoline earns its 3 with a flash point of about minus 45 F. Diesel's flash point is 125 F or higher, which is why it is a 2 and not a 3. Propane is a gas at room temperature with a boiling point of minus 44 F, so it is a 4 on flammability regardless of which health number your supplier picks.

Solvents

Chemical Rating (H-F-I) Special Supplier variation Print Pro AZ part
Acetone 1-3-0 none SS-043
Ethanol 2-3-0 none denatured blends vary SS-044
Methanol* 1-3-0 none some 2-3-0 SS-037 / SS-003
Isopropyl alcohol* 1-3-0 none some 2-3-0 SS-003
Toluene 2-3-0 none SS-007
Xylene 2-3-0 none SS-007
MEK (methyl ethyl ketone) 1-3-0 none SS-003
Hexane 1-3-0 none SS-003
Mineral spirits* 1-2-0 none suppliers differ SS-001
Lacquer thinner 2-3-0 none SS-007
Ethylene glycol* 2-1-0 none suppliers differ SS-018
Acetylene 0-4-3 none blank + kit

Acetone, CAS 67-64-1, has a flash point of about minus 4 F, well under the 73 F line for a 3. Ethanol, CAS 64-17-5, flashes at about 55 F. Acetylene is the outlier in the group with a 3 on instability, because it can decompose explosively under pressure.

Acids

Chemical Rating (H-F-I) Special Supplier variation Print Pro AZ part
Sulfuric acid, concentrated 3-0-2 W dilute solutions rate lower SS-046
Hydrochloric (muriatic) acid 3-0-0 none SS-047
Nitric acid* 4-0-0 OX some 3-0-0 OX SS-014 art
Phosphoric acid* 3-0-0 none some 2-0-0 SS-006
Acetic acid, glacial* 3-2-0 none some 2-2-0 SS-023
Hydrofluoric acid 4-0-0 none blank + kit
Citric acid 1-1-0 none SS-011

Concentrated sulfuric acid, CAS 7664-93-9, carries the W symbol because it reacts exothermically with water, which is why you always add acid to water and never the reverse. Hydrochloric acid, CAS 7647-01-0, is the muriatic acid in every pool room, rated 3-0-0.

Bases

Chemical Rating (H-F-I) Special Supplier variation Print Pro AZ part
Sodium hydroxide 3-0-1 none dilute solutions rate lower SS-048
Potassium hydroxide 3-0-1 none SS-015
Ammonium hydroxide 3-1-0 none SS-004
Anhydrous ammonia* 3-1-0 none R-717 refrigeration often 3-3-0 SS-004 / SS-008
Sodium carbonate* 2-0-0 none suppliers differ SS-030

Sodium hydroxide, CAS 1310-73-2, gets a 1 on instability because it generates heat when dissolved in water. Anhydrous ammonia in refrigeration systems is the one to watch; the R-717 SDS from many suppliers rates it 3-3-0, so check yours before you placard the machine room.

Oxidizers and Pool Chemicals

Chemical Rating (H-F-I) Special Supplier variation Print Pro AZ part
Hydrogen peroxide, 30 to 35%* 3-0-1 OX 3% household is 1-0-0 custom
Sodium hypochlorite (bleach)* 2-0-1 OX on some 12% pool bleach often 3-0-1 custom
Calcium hypochlorite (pool shock) 3-0-2 OX custom
Potassium permanganate* 1-0-0 OX suppliers differ custom
Chlorine gas 4-0-0 OX SS-014
Oxygen, compressed 0-0-0 OX liquid oxygen is 3-0-0 OX SS-019 / SS-010

Every chemical in this group can feed a fire with oxygen, which is what the OX symbol tells a firefighter. Pool operators should note that bleach concentration drives the rating: household strength and 12% pool bleach do not share a diamond.

Gases

Chemical Rating (H-F-I) Special Supplier variation Print Pro AZ part
Nitrogen 0-0-0 SA liquid nitrogen is 3-0-0 SA SS-024 / SS-012
Argon 0-0-0 SA blank + kit
Helium 0-0-0 SA blank + kit
Carbon dioxide* 0-0-0 SA some 2-0-0 SA blank + kit
Hydrogen 0-4-0 none SS-029
Propylene 1-4-1 SA on some SS-027 / SS-028

SA means simple asphyxiant, a gas that displaces oxygen. NFPA 704 allows it only for nitrogen, helium, neon, argon, krypton, xenon and liquefied carbon dioxide. A 0-0-0 diamond with SA is not a harmless room; it is a room where a leak can drop the oxygen level without any warning smell.

Other

Chemical Rating (H-F-I) Special Supplier variation Print Pro AZ part
Formaldehyde, 37%* 3-2-0 none suppliers differ SS-023
Lithium-ion battery rooms per AHJ none no fixed rating SS-050
Calcium chloride* 1-0-0 none some 0-0-0 SS-049
Water 0-0-0 none SS-049
Sodium chloride (salt) 0-0-0 none SS-049
Sodium bicarbonate (baking soda) 0-0-0 none SS-049

Water, salt and baking soda are 0-0-0 because they meet the lowest criteria in every category. They still get a diamond because a placarded building rates every room, and a missing diamond reads as a missing rating. Lithium-ion has no fixed rating at all; the fire marshal sets it.

What Do the Special Hazard Symbols in the Chart Mean?

The chart uses only the three symbols NFPA 704 authorizes in the white square: W with a horizontal line through it, OX and SA. Each one tells a responder something the numbers cannot.

  • W with a line through it means the material reacts dangerously or unusually with water. Concentrated sulfuric acid, sodium metal and calcium carbide carry it. A firefighter seeing it will not open a hose line on the spill.
  • OX means oxidizer. The material can supply oxygen to a fire without outside air. Hydrogen peroxide, chlorine, nitric acid and calcium hypochlorite carry it.
  • SA means simple asphyxiant gas. It applies only to the seven gases listed in the Gases section.

COR, ACID, ALK, BIO, POI and the radiation trefoil are not part of NFPA 704. They show up on older signs and some SDS sheets. If your facility uses them, NFPA 704 says to place them outside the diamond, and a strict fire marshal can call them non-compliant inside the white square.

How Do You Rate a Room With Several Chemicals?

You rate the room at the highest number present in each color from any material, plus every special symbol present. It is worst case, not average, and the facility owner or operator assigns it.

Take a typical pool chemical room. It holds muriatic acid at 3-0-0, calcium hypochlorite at 3-0-2 with OX, and sodium bicarbonate at 0-0-0.

Health is 3 (from either the acid or the shock), flammability is 0, and instability is 2 (from the shock). The white square gets OX. The door placard reads 3-0-2 with OX, even though two of the three chemicals would rate lower on their own.

Do this for every room, cabinet and tank that the fire code requires you to placard. IFC Section 5003.5 requires hazard identification signs as specified in NFPA 704 on stationary containers and above-ground tanks, and at entrances to locations where hazardous materials are stored, dispensed, used or handled in quantities requiring a permit. If the arithmetic across a long inventory list is more than you want to do, Print Pro AZ takes a chemical inventory in PDF, Excel or CSV and returns the full placard set with the composite room rating worked out. Send us your chemical inventory and it comes back as a sign schedule.

Which Sign Do You Post Once You Have the Rating?

Post a diamond sized for the viewing distance, in vinyl indoors and .040 aluminum outdoors. NFPA 704 Table 9.1 sets the minimum: a 4 inch diamond with 1 inch numerals for 50 feet, 6 inches for 75 feet, 8 inches for 100 feet, 12 inches for 200 feet, and 15 inches for 300 feet. Verify the edition your AHJ adopted.

Print Pro AZ prints the NFPA 704 diamond signs in 3, 9, 11, 15, 20 and 24 inch, as a vinyl label or rust-free aluminum, with black or white numerals. The 3 to 9 inch vinyl sizes cover cabinets, containers and interior doors. The 15 inch and larger aluminum sizes cover exterior doors and tanks, where the Arizona sun fades vinyl within a season.

Mount it at eye level or above the door, visible by flashlight, clear of the door swing. NFPA 704 Chapter 9 recommends placards on two exterior walls with access, at each access point to a room or area, at each principal entrance to an exterior storage area, and on stationary tanks large enough to warrant a response. Partner companies that placard every room from a worked-out inventory report 45%+ better first-time inspection pass rates.

Where Can You Read More About Each Chemical?

Each of the most common chemicals in the chart has its own post that explains the rating number by number, the special symbol or lack of one, the supplier variation, and which sign to post. Start with the one you stock the most of.

Preview of the NFPA 704 Diamond Field Guide PDF
Free download · 2-page field guide

Take the field guide with you

Everything in this article on one printable card: the rating scales, the white square symbols, placement rules, and 50 chemical ratings. Free to share with your crew.

The download link appears instantly. No spam, and you can unsubscribe anytime.

NFPA 704 diamond sign printed by Print Pro AZ
NFPA 704 placards · printed in Phoenix

Ready to placard the building? Get a quote in one business day.

Tell us the rooms, tanks and chemicals. We handle the rest, from the composite rating to an aluminum placard the fire marshal can read from the street.

Start my quote

Or browse NFPA 704 diamond signs and order online.

Frequently Asked Questions

Is there an NFPA 704 chemical list PDF I can print?

Yes. The free NFPA 704 Diamond Field Guide is a two-page PDF: page one covers how to read the diamond and where it goes, and page two lists ratings for the 50 common chemicals in this chart with Print Pro AZ part numbers. Use the download form on this page to get it.

What is the NFPA rating for gasoline?

Gasoline is rated 1-3-0 with no special symbol: health 1, flammability 3, instability 0. Its flash point of about minus 45 F puts it below the 73 F line for flammability 3, with a boiling point above 100 F, which keeps it out of the 4 category.

Why is diesel a 2 on flammability when gasoline is a 3?

Diesel's flash point is 125 F or higher, which lands in the 100 F to 200 F band for flammability 2. Gasoline flashes at about minus 45 F, far below the 73 F line for a 3. Diesel suppliers do disagree on the health number, so you will see 0-2-0, 1-2-0 and 2-2-0 on different SDSs.

Why do water, salt and baking soda get an NFPA diamond?

Because a placarded building rates every room, and a room with no diamond reads as a room with no rating. Water, sodium chloride and sodium bicarbonate meet the lowest criteria in every category, so they carry 0-0-0. The diamond tells the responder the room was evaluated and holds nothing hazardous.

Who assigns the NFPA 704 rating for my facility?

You do, as the facility owner or operator. NFPA 704 gives the criteria for each number and symbol, and the SDS gives the data. Suppliers often print a rating in SDS Section 16 as a starting point, but the number on your door is your responsibility, and the fire marshal can ask how you arrived at it.

Conclusion

This NFPA 704 chemical list covers 50 common chemicals with ratings from 0-0-0 for water up to 4-0-0 with OX for chlorine gas, grouped the way they sit in real storage rooms. Asterisked chemicals vary by supplier, so the SDS for your exact product and concentration is the final word. Every room gets rated at the highest number in each color from any material inside, plus every special symbol, and you as the facility owner assign that rating.

Getting the numbers right on the first order saves you a rejected placard and a re-inspection. Shop the NFPA diamond collection for stock ratings, or send Print Pro AZ your chemical inventory and get the full placard set back with every room worked out. Questions? Call Brent at (602) 649-5305.

Sources

Brent Hanke | Print Pro AZ | (602) 649-5305 | b.hanke@printproaz.com

Brent Hanke is the founder of Print Pro AZ, supplying NEC-compliant labels to contractors across the country.


Tags:
NFPA 704 Placards for Lithium-Ion Battery and ESS Rooms

Acetone NFPA 704 Rating and Diamond Explained